To set speed for all the ports on the switch Note – 0 :auto negotiated 1,2,4 Gbit/ sec, 1 : 1Gbit/ sec, 2 : 2 Gbit/ sec, 4 : 4Gbit/ sec To set speed for a port Note – 0 :auto negotiated 1,2,4 Gbit/ sec, 1 : 1Gbit/ sec, 2 : 2 Gbit/ sec, 4 : 4Gbit/ sec To enable a port, status would not change even after rebooting the switch To disable a port, status would not change even after rebooting the switch The two sites are connected via a WAN link. I was involved for a project for one of our customers that involved configuring remote replication between two Sun 6180 storage boxes, one located in Cairo and the other located in Port Said (which is 200km away). SAN zoning is a method of creating logical groups over the physical configuration of the fabric and allowing communication / access of Fibre Channel devices by grouping them. Replication Using FCIP & Brocade 7800 SAN switches. Posted By Rajesh Radhakrishnan March 13 2018.
For better understanding of the commands, let us first understand the day to day operational challenges faced in the SAN fabric. How to create zones from CLI on a Brocade SAN Switch.
High availability, heartbeat and synchronizationĪ registered state change registration is suppressed when a state change occurs on the portĪ registered state change registration is sent when a state change occurs on the port We have already discussed about, Brocade SAN switch Zoning steps Via CLI and CISCO MDS Zoning steps via CLI This write-up, focuses on the basic trouble shooting commands used in Brocade SAN switch. Ensure all switches in a fabric have the same parameters in order to communicateĭisplays the PID set for a switch Core, Native or Extended edgeĭisplays the current firmware version on the switchĭisplays the status of local and remote CP’s. file, which was uploaded from a different type of switch, may cause this switch to fail. switch, this files configuration settings will override.
So modify the procedure according the user choice.Displays the status of the temperature readingsĭisplays the status of the sensor readingsĭisplays the information in the name server along with the state change registration detailsĭisplays detailed information of all the devices connected to all the switches in the fabric (Remote Name Servers)ĭisplays the 24 bit address of all devices that are in the fabricĭisplays all the licenses that have been added in the switchĭisplays the current date set on the switchĭisplays the banner that will appear when logging in unsing the CLI or webtoolsĭisplays the JAVA version the switch expects at the management consoleĭisplays information of all the switches in the fabricĭisplays the account information like role, description, password exp date, locked statusĭisplays the overall status of the switchĭisplays policy set for the switch regarding Marginal (Yellow) or Down (Red) error statusĭisplays the speed set for all ports on all slots and other detailed port informationĭisplays the parameters of the switch. This command is used to download a backed-up configuration. Note: Some of the steps might not be required based on the user scenario (deletion of host alias or array alias if the host or array ports is still zoned).
Below procedure explains how to remove the zones from active configuration and delete zones & alias from zone database. Create the storage zones using the aliases on each switch.
To enable NPIV on all other Brocade Fibre Channel Switches, use the following Fabric OS CLI procedure: To enable or disable NPIV on a port-by-port basis, use the portCfgNPIVPort command. Login to the server and verify the HBA connection. For additional information on usage of the portCfgNPIVPort command, see the Brocade switch firmware documentation. Each storage controller must have four initiator ports available to connect to the switch fabrics. The four supported Brocade switches must be connected to two fabrics of two switches each, with each fabric spanning both sites. Zone removal/deletion can be done to clean up SAN fabric when a host is not using SAN storage or when a host/array is decommissioned. How to zone a Brocade SAN switch in command line base Plug in the FC Connector into an open port on the switch. Move an FC SAN workload from MetroCluster FC to MetroCluster IP nodes.